Model Validation and Uncertainty Quantification, Volume 3

170 Y. Zhang et al. References 1. ASCE (2013) Minimum design loads for buildings and other structures. American Society of Civil Engineers, Reston, VA 2. Friswell M, Mottershead JE (1995) Finite element model updating in structural dynamics. Springer, London, UK 3. Brincker R, Zhang L, Andersen P (2001) Modal identification of output-only systems using frequency domain. Smart Mater Struct 10(3):441–445 4. Ljung L (1999) System identification. Wiley, New York, NY 5. Peeters B, De Roeck G (1999) Reference-based stochastic subspace identification for output-only modal analysis. Mech Syst Signal Process 13(6):855–878 6. Hua XG, Ni YQ, Ko JM, Wong KY (2007) Modeling of temperature – frequency correlation using combined principal component analysis and support. J Comput Civ Eng 21(4):122–135 7. Zhang Y, Lynch JP (2013) Long-term modal analysis of the New Carquinez Long-Span Suspension Bridge. In: Cunha A (ed) Topics in dynamics of bridges, vol 3, Conference proceedings of the society for experimental mechanics series. Springer, Berlin, pp 73–82 8. Moser P, Moaveni B (2011) Environmental effects on the identified natural frequencies of the Dowling Hall Footbridge. Mech Syst Signal Process 25(7):2336–2357 9. Cross EJ, Koo KY, Brownjohn JMW, Worden K (2013) Long-term monitoring and data analysis of the Tamar Bridge. Mech Syst Signal Process 35(1–2):16–34 10. Peeters B, De Roeck G (2001) One year monitoring of the Z24-bridge: environmental influences versus damage events. Earthq Eng Struct Dyn 30:147–171 11. Liu C, Dewolf JT (2007) Effect of temperature on modal variability of a curved concrete bridge under ambient loads. J Struct Eng 133(12):1742–1751 12. Yim J (2009) Long-term structural health monitoring for long span bridges - temperature and traffic effects, Ph.D. Dissertation, University of Illinois Chicago 13. Soyoz S, Feng MQ (2009) Long-term monitoring and identification of bridge structural parameters. Comput Aid Civil Infrastruct Eng 24(2):82–92 14. Kurata M, Kim J, Lynch JP, Van Der Linden GW, Sedarat H, Thometz E, Hipley P, Sheng L (2013) Internet-enabled wireless structural monitoring systems: development and permanent deployment at the New Carquinez Suspension Bridge. J Struct Eng 139(10):1688–1702 15. Kim J, Lynch JP (2011) Comparison study of output-only subspace and frequency-domain methods for system identification of base excited civil engineering structures. In: Proulx T (ed) Civil engineering topics, vol 4, Conference proceedings of the society for experimental mechanics series. Springer, Berlin, pp 305–312 16. Swartz R, Jung D, Lynch J, Wang Y, Shi D, Flynn M (2005) Design of a wireless sensor for scalable distributed in-network computation in a structural health monitoring system. In: 5th international workshop on structural health monitoring, Stanford, CA, September 12–14 17. Allemang RJ (2003) The modal assurance criterion – twenty years of use and abuse. Sound and Vibration 1(8):14–21 18. Häckell MW, Rolfes R (2013) Monitoring a 5MW offshore wind energy converter—condition parameters and triangulation based extraction of modal parameters. Mech Syst Signal Process 40(1):322–343 19. Van Overschee P, De Moor B (1996) Subspace identification for linear systems: theory, implementation, applications. Kluwer Academic Publishers, Dordrecht, Netherlands 20. Peeters B, De Roeck G (2001) Stochastic system identification for operational modal analysis: a review. J Dyn Syst Meas Control 123:659 21. Brownjohn JMW, Magalhaes F, Caetano E, Cunha A (2010) Ambient vibration re-testing and operational modal analysis of the Humber Bridge. Eng Struct 32(8):2003–2018 22. Hu W, Moutinho C, Magalhaes F, Caetano E, Cunha A (2009) Analysis and extraction of temperature effects on natural frequencies of a footbridge based on continuous dynamic monitoring. In: IOMAC-09: international operational modal analysis conference, Ancona, Italy, pp 55–62

RkJQdWJsaXNoZXIy MTMzNzEzMQ==